Skip Navigation Links

Bath and circulation thermostats with natural refrigerant  |  KISS • Ministat • Compatible Control 

Environmentally-friendly with natural refrigerants
As a pioneer in refrigeration technology we have been using hydrocarbons in our products for many years. Already in the early 1970s, company founder Peter Huber started researching and using natural refrigerants. In the following years, Propane and Propene have been used as a standard refrigerant in many units.

In practice, natural refrigerants have significant advantages over their synthetic derivatives, e.g. very good thermodynamic properties. Advantages include low pressure losses in pipelines and heat exchangers, low energy consumption during compression, lower amounts of refrigerant required and good material compatibility.
 
KISS • Ministat • Compatible Control with natural refrigerants
The circulators are split into two product lines, the CC-models and the simpler KISS models. Both product lines represent classically constructed laboratory circulators with open baths. Baths and circulators for heating applications up to +300 °C are available, as well as models for heating and cooling applications from -90 °C to +200 °C. Immersion or bridge circulators are suitable for thermal control of existing baths. The Ministat, the smallest cooling and heating circulator in the world, is the first choice for operation in fume-hoods or integrating into systems.
  
   
 
Temperiertechnik: Bath and circulation thermostats der Modellreihe KISS • Ministat • Compatible Control

View options:  Disable variants    Enable miniature pictures

HUBER
Order No.
HUBER
Model
Temp.
range
°C
Temp.
stability
°C
Heating
capacity
kW
Cooling
capacity
kW
Pump performance
Pressure  Suction 
l/min  bar  l/min  bar 
Bad-/Füll-
volumen
Liter
Fill
vol.
Litres
Bath opening/
bath depth
WxD / BD mm
Mains
voltage
Eco
 
Cooling circulators with natural refrigerants KISS • Ministat • Compatible Control  
2009.0020.98   KISS K12   -20...200  ±0,05   2   0,2 @ 0°C  
14   0,25   10,5   0,17  
12 290 x 152 / 150 int. + ext. 230V 1~ 50/60Hz
 
2010.0017.98   KISS K15   -20...200  ±0,05   2   0,2 @ 0°C  
14   0,25   10,5   0,17  
15 290 x 152 / 200 int. + ext. 230V 1~ 50/60Hz
 
2011.0013.98   KISS K20   -30...200  ±0,05   2   0,35 @ 0°C  
14   0,25   10,5   0,17  
20 290 x 329 / 150 int. + ext. 230V 1~ 50/60Hz
 
2012.0015.98   KISS K25   -30...200  ±0,05   2   0,35 @ 0°C  
14   0,25   10,5   0,17  
25 290 x 329 / 200 int. + ext. 230V 1~ 50/60Hz
 
2008.0043.98   KISS K6   -25...200  ±0,05   2   0,15 @ 0°C  
14   0,25   10,5   0,17  
4,5 140 x 120 / 150 int. + ext. 230V 1~ 50/60Hz
 
2008.0044.98   KISS K6s   -25...200  ±0,05   2   0,21 @ 0°C  
14   0,25   10,5   0,17  
4,5 140 x 120 / 150 int. + ext. 230V 1~ 50/60Hz
 
2014.0011.01   Ministat 125   -25...150  ±0,02   1   0,21 @ 0°C  
22   0,7   16   0,4  
2,75 178 x 80 / 120 int. + ext. 230V 1~ 50/60Hz
 
2014.0006.01   Ministat 125w   -25...150  ±0,02   1   0,2 @ 0°C  
22   0,7   16   0,4  
2,75 178 x 80 / 120 int. + ext. 230V 1~ 50/60Hz
 
2015.0005.01   Ministat 230   -40...200  ±0,02   2   0,38 @ 0°C  
22   0,7   16   0,4  
3,2 170 x 85 / 135 int. + ext. 230V 1~ 50/60Hz
 
2015.0007.01   Ministat 230w   -40...200  ±0,02   2   0,38 @ 0°C  
22   0,7   16   0,4  
3,2 170 x 85 / 135 int. + ext. 230V 1~ 50/60Hz
 
2016.0005.01   Ministat 240   -45...200  ±0,02   2   0,55 @ 0°C  
22   0,7   16   0,4  
4,9 205 x 85 / 157 int. + ext. 230V 1~ 50/60Hz
 
2016.0006.01   Ministat 240w   -45...200  ±0,02   2   0,55 @ 0°C  
22   0,7   16   0,4  
4,9 205 x 85 / 157 int. + ext. 230V 1~ 50/60Hz
 
2018.0023.01   CC-508   -55...200  ±0,02   3   1,5 @ 0°C  
25   0,7   18,5   0,4  
5 120 x 110 / 160 int. + ext. 230V 1~ 50Hz
 
2018.0026.01   CC-508w   -55...200  ±0,02   3   1,5 @ 0°C  
25   0,7   18,5   0,4  
5 120 x 110 / 160 int. + ext. 230V 1~ 50Hz
 
2009.0002.01   CC-K12   -20...200  ±0,02   2   0,2 @ 0°C  
27   0,7   22   0,4  
12 290 x 152 / 150 int. + ext. 230V 1~ 50/60Hz
 
2010.0002.01   CC-K15   -20...200  ±0,02   2   0,2 @ 0°C  
27   0,7   22   0,4  
15 290 x 152 / 200 int. + ext. 230V 1~ 50/60Hz
 
2011.0002.01   CC-K20   -30...200  ±0,02   2   0,35 @ 0°C  
27   0,7   22   0,4  
20 290 x 329 / 150 int. + ext. 230V 1~ 50/60Hz
 
2012.0002.01   CC-K25   -30...200  ±0,02   2   0,35 @ 0°C  
27   0,7   22   0,4  
25 290 x 329 / 200 int. + ext. 230V 1~ 50/60Hz
 
2008.0005.01   CC-K6   -25...200  ±0,02   2   0,15 @ 0°C  
27   0,7   22   0,4  
4,5 140 x 120 / 150 int. + ext. 230V 1~ 50/60Hz
 
2008.0002.01   CC-K6s   -25...200  ±0,02   2   0,21 @ 0°C  
27   0,7   22   0,4  
4,5 140 x 120 / 150 int. + ext. 230V 1~ 50/60Hz
 
2013.0003.01   Variostat   -30...150  ±0,02   1   0,2 @ 0°C  
25   0,7   18,5   0,4  
-- -- int. + ext. 230V 1~ 50/60Hz
 
Model description: w=water cooled, P=strong pressure pump, H=heater integrated, EO=external open, T=Tower housing, OLÉ=Basic controller (further options on request)
Peter Huber Kältemaschinenbau Home  |  Contact  |  Terms & Conditions  |  Imprint  |  Sitemap